Contents
CONTOUR 7000 STANDARD MODELS Page
Introduction and Operating Instructions . . . . . . . . . . . . 2
Installation Instructions
- Fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
- Plumbing (Over and Undersink) . . . . . . . . . . 2
- Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Draining the Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Recommended Accessories. . . . . . . . . . . . . . . . . . . . . 7
CONTOUR 7000 REMOTE MODELS WITH
AIR SWITCH AND REMOTE SWIVEL SPOUT
Introduction and Operating Instructions . . . . . . . . . . . . 4
Installation Instructions
- Fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
- Plumbing (Over and Undersink) . . . . . . . . . . . 5
- Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Draining the Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Recommended Accessories. . . . . . . . . . . . . . . . . . . . . 7
GENERAL
Fault Diagnosis (Self Help) . . . . . . . . . . . . . . . . . . . . . 7
Technical Data Summary . . . . . . . . . . . . . . . . . . . . . . 7
Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 7
After Sales Service . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
THIS MODEL IS SUPPLIED
COMPLETE WITH VENTED OUTLET
ARM.
TAPS OR ANY OTHER OUTLET
MUST NOT BE FITTED TO THIS
MODEL UNLESS RECOMMENDED
BY REDRING
CONTOUR 7000 SERIES Vented (Open Outlet) Water Storage Heater
Installation/User Instructions
This appliance is not intended for use by persons
(including children and the infirm) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that
they do not play with the appliance.
Contour 7000 Standard Models
These instructions should be read in full before commencing the installation.
We recommend that the installation should only carried out by a suitably qualified person.
The Redring Contour 7000 is an open-outlet, thermal Storage water heater for use with Redring recommended fittings
for one outlet only.
It operates on the displacement principle ie: when cold water is admitted into the bottom of the tank, hot water flows out
through the outlet.
There are two models: 3kW, which ensures a rapid reheating of the water and a 1kW unit to suit special electrical
requirements.
In addition to the thermostat which controls the temperature of the water in normal use, a safety cut -out is fitted in the
form of a thermal fuse. This switches off the electricity to the heater when it senses an abnormally high temperature
eg. if the unit is run without water. Replacement thermal fuses can be obtained.
Operating Instructions
If the heater is used regularly it is recommended that it is left on at all times, the thick insulation ensures economic
running costs. The water is turned on and off via the water control tap.
Setting the temperature
The four settings indicated by the thermostat are:-
This gives very hot water, which can be mixed with cold water to produce quantities of usable water greater
than the actual capacity of the heater.
This setting will deliver, direct water suitable for washing up.
This setting will deliver, direct, water suitable for hand wa shing.
This setting will maintain the water in the heater just above freezing point if the heater is to be left unattended
whilst subject to freezing conditions. The electricity must be left on for this facility.
Water expands when heated, thus during the initial heating of cold water admitted to the heater, drips from the outlet
spout may occur.
If it is required that the adjustment of the thermostat is not available to the user of the heater, then after first establishing
that the temperature is as required, the control cover can be locked off using the locking screw provided.
ATTENTION
CONTOUR 7000
REMOTE
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Setting the temperature

8 APPLIED ENERGY PRODUCTS LIMITED MORLEY WAY, PETERBOROUGH PE2 9JJ TEL +44 (0) 844 372 7750 / FAX: +44 (0) 844 372 7760 Website: www.redring.

Page 2

2 Installation Instructions REMOVING THE FRONT COVER 1. Remove the thermostat fixing screw and cover. 2. Remove the thermostat knob by pulling

Page 3

6 Outlet Pipe and Air Switch Assembly Electrical Connection The installation must be in accordance with the current BS.7671 (IEE Wiring Regulatio

Page 4 - Contour 7000 Remote Models

4 Suggested Installation Plans for Redring Contour 7000 Contour 7000 Remote Models These instructions should be read in full before commencing